g-box
    Small, Profitable & Quiet
    g-box 60 kW

    The g-box is 2G’s profitable small power plant with an electrical output of up to 60 kW. The connection-ready module includes a control cabinet with a PLC controller. While the powerful unit works extremely efficiently, the low noise output makes it suitable for various applications like hotels, offices, or residential buildings.

    • Connection-ready for easy integration
    • Compact design requires minimal space for installation
    • Super-silent and fully enclosed compact module (max 55 dB(A) at a distance of 3 ft)
    • Very economical – highest thermal efficiencies through condensing technology
    • Completely water-cooled – no need for costly installation of air ducts
    • High availability, reliability, and low-maintenance
    • Island mode/black start capable

    Request a Quote  |  Download g-box Brochure

    Technical Details

    Natural Gas

    Type Output Efficiency
      Electrical Thermal Electrical Thermal total
    g-box 50 60 kW 423 MBTU 34.3 % 71.0 % 105.3 %
    aura_100-420 kW
    Clean & Efficient
    aura100 - 420 kW

    Equipped with 2G‘s proprietary Lambda 1 technology and low-charged turbocharger, it is also characterized by extremely low exhaust emissions and meets, in particular, the increasingly stringent requirements for low nitrogen oxide limits.

    •  Low emissions
    •  High heat efficiency
    •  Reliable, service-friendly motor
    •  Specifically higher performance than 15 % of conventional systems with the same displacement
    •  Designed as a ready-to-connect compact module

    Request a Quote | Download aura brochure 

    Technical Details

    Natural Gas

    Type Output Efficiency
      electrical thermal electrical thermal total
    aura 404 100 kW 525 MBTU 35.9 % 54.9 % 90.8 %
    aura 406 170 kW 808 MBTU 35.4 % 55.8 % 91.2 %
    aura 408 280 kW 1,493 MBTU 37.1 % 58.0 % 95.1 %
    aura 412 420 kW 2,235 MBTU 37.2 % 58.0 % 95.2 %
    agenitor 404
    Evolution in Efficiency
    agenitor100 - 450 kW

    The agenitor by 2G is the result of intensive work by the 2G research and development team. Improving combustion chamber geometry has made it possible to increase the efficiency of the agenitor significantly.

    • Highly efficient power plant with an optimized gas engine – and therefore lower fuel costs
    • Modular design facilitates installation in hard-to-reach places
    • Very reliable even in regular start-stop operation thanks to highly wear-resistant engine components
    • Resilient and low-maintenance
    • Available as a twin pack configuration with two modules per container for twice the power

    Request a Quote  |  Download agenitor natural gas brochure

    Technical Details

    Natural Gas

    Type Output Efficiency
      electrical thermal electrical thermal total
    agenitor 404b 100 kW 416 MBTU 36.9 % 45.0 % 81.9 %
    agenitor 404c 160 kW 610 MBTU 39.7 % 44.3 % 84.0 %
    agenitor 406 250 kW 938 MBTU 40.6 % 44.7 % 85.3 %
    agenitor 408 360 kW 1,361 MBTU 40.9 % 45.3 % 86.2 %
    agenitor 412 450 kW 1,634 MBTU 40.2 % 42.8 % 83.0 %
    avus 500plus
    Built for Big Tasks
    avus499 - 2,500 kW

    The avus is a highly efficient 2G power plant for high electric power consumption (above 500 kW), which is used in larger industrial projects or for supplying microgrids. The modular built systems include all components and are easy to install.

    • Interconnection of multiple units allows for higher electrical output. A Master Control system enables synchronization and load sharing to up to 5 modules.
    • Efficient running mode and operating times due to excellent engine quality

    Request a Quote  |  Download avus natural gas brochure

    Technical Details

    Natural Gas

    Type Output Efficiency
      electrical thermal electrical thermal total
    avus 500plus - Mexico Specific 499 kW 1,941 MBTU 39.7 % 45.3 % 85.0 %
    avus 500plus 550 kW 2,084 MBTU 40.6 % 45.1 % 85.7 %
    avus 600c 600 kW 2,320 MBTU 42.2 % 45.9 % 88.1 %
    avus 800c 800 kW 3,043 MBTU 42.4 % 45.7 % 88.1 %
    avus 1000plus 1,000 kW 3,608 MBTU 42.3 % 44.7 % 87.0 %
    avus 1200c 1,200 kW 4,080 MBTU 43.4 % 43.2 % 86.6 %
    avus 1200e 1,509 kW 5,537 MBTU 43.7 % 46.1 % 89.8%
    avus 1500c 1,560 kW 5,421 MBTU 43.0 % 43.8 % 86.8 %
    avus 1600e 2,014 kW 7,407 MBTU 43.3 % 46.7 % 90.0 %
    avus 2000c 2,000 kW 6,793 MBTU 43.4 % 43.2 % 86.6 %
    avus 2000e 2,521 kW 9,283 MBTU 43.6 % 46.7 % 90.3 %

    Containerized Solutions

    2G power plants can be installed in various ways – depending on local conditions and the requirements for sound insulation. They can therefore be incorporated in existing buildings or heating systems or can be set up separately in a container or engine room. With the appropriate sound insulation package, noise emission can be as low as 35 dB (A) at a distance of 10 m.

    Compact Container

    Compact Container Sizes Available

     

    19.7 ft x 8 ft x 9.2 ft

    Acoustic Emissions

     

    Standard: 65 dB (A)
    Super silent: up to 55 dB (A)

    Standard Container

    Standard Container Sizes Available

     

    21.3 ft x 9.8 ft x 9.8 ft
    29.5 ft x 9.8 ft x 9.8 ft
    34.4 ft x 9.8 ft x 9.8 ft
    39.4 ft x 9.8 ft x 9.8 ft

    Acoustic Emissions

     

    Standard: 65 dB (A)
    Super silent: up to 52 dB (A)

    High Line Container

    High Line Container Sizes Available

     

    29.5 ft x 9.8 ft x 12.1 ft
    34.4 ft x 9.8 ft x 12.1 ft
    39.4 ft x 9.8 ft x 12.1 ft
    39.4 ft x 14.1 ft x 17.5 ft

    Acoustic Emissions

     

    Standard: 65 dB (A)
    Super silent: up to 45 dB (A)

    Container Twin Pack

    Container Twin Pack Sizes Available

     

    42.7 ft x 9.8 ft x 9.8 ft
    49.2 ft x 9.8 ft x 9.8 ft

    Acoustic Emissions

     

    Standard: 65 dB (A)
    Super silent: up to 52 dB (A)

    Outdoor Sound Capsule

    Outdoor Sound Capsule Sizes Available

     

    Depending on product

    Acoustic Emissions

     

    Standard: 65 dB (A)

    Sound Capsule

    Sound Capsule Sizes Available

     

    Depending on product

    Acoustic Emissions

     

    Standard: 65 dB (A)

    Natural Gas Case Studies

    aura404_container_fixed

    New Haven Non-Profit Assisted Living Facility - New Haven, CT

    Project Profile

    The Towers at Tower Lane, residing in New Haven, Connecticut, utilizes (1) aura 404 with an output of 100kW. This facility is a distinctive non-profit apartment and assisted living retirement community in the heart of one of New England's most historic and vital cities. This unit will produce 40% of this facility's energy through cogeneration with hot water recovery, allowing the facility to utilize the savings to feed those elderly residents who live on a fixed income through a food sustainability program. The project makes meals more accessible and affordable, improving nutrition for those in need for the next 25 years.

    Screen Shot 2023-01-13 at 4.51.58 PM

    Texas Wesleyan University - Fort Worth, TX

    Project Profile

    Texas Wesleyan University launched a $6.2 Million energy-saving project in 2015. The centerpiece of this project is 2G Energy's avus 800, a CHP that provides power to much of the campus spanning 83 acres. The natural gas-powered CHP plant supplies 80% of the power to 80% of the campus while reducing the university's dependency on the public power grid. The new power plant includes a 250-ton absorption chiller, a new cooling tower, new heating boilers, pumping systems, and central plant optimization controls. The self-funded project will pay for itself in cost savings quickly. The power system is expected to save $377,000 and 5.9 million kilowatt-hours per year.

    edenresort-lancaster-pa1

    Eden Resort - Lancaster, PA

    Project Profile

    2G Energy Inc. received the order to manufacture and supply a 2G patruus rated 400 ekW/h with a yearly capacity of 3,320 MWh electrical output and 15,756 mmBTU thermal energy generation. This fully-containerized CHP system was supplied in High-Line Configuration for more pleasing optics and with a reduced noise level of <50 dB(A) @ 30' to ensure a very quiet ambiance around the hotel. The High-Line CHP Module was delivered in the hotel's color and skillfully integrated into the existing resort infrastructure, considering hotel guest experience and limitations on space. The hotel is now enjoying significant cost savings, and this project demonstrates how easy it is for hotel owners to reduce their energy expenses.